Rewarder Custom Headers 

Home Up Search Checkout

Reversion

Headers
NHRA Mufflers
Pre-Owned
Coatings
Apparel
Links
What's New
Reader Rides
Contents
Contact Us

Water Reversion/Ingestion

VERY IMPORTANT NOTICE, PLEASE READ CAREFULLY!!!

Reversion, what is it?  It is simply the exhaust pulse flowing backwards momentarily during the overlap phase of the camshaft at low cycling rates.  During the overlap phase the piston is pushing out the last of the exhaust gases and prior to reaching top dead center (T.D.C) the intake valve and the exhaust valve is still closing.   At this point in the engine cycle both valves are in the open position.  At high cycling rates the inertia of the incoming intake charge and the outgoing exhaust pulses keep the exhaust flowing in the proper direction.  But at low cycling rates, as the piston is pushing out the last of the exhaust gases the intake valve opens and some of the spent exhaust charge is pushed into the intake manifold.  As the piston reaches T.D.C. and begins the intake stroke the exhaust valve is still not completely closed.  As a result, the piston pulls from the intake and exhaust valves simultaneously causing the exhaust gases to flow in a reverse direction.  This is normally not a problem until you add water into the exhaust stream.  Reversion can be severe enough to stall the engine, add water to the oil, rust the exhaust seats, etc.   This effect only happens at idle speeds, but remember that during shut down the engine encounters the greatest reversion.

For these reasons Rewarder Custom Headers has guidelines for camshaft selection.   Our guidelines are based on 454 c.i. with a 285 degree camshaft (242 at .050), on a 114 degree lobe center.  Larger cams may cause reversion.  These figures are just guidelines.  Cubic inches, valve size, exhaust valve timing, etc., all will have an effect on reversion.  The only true test is to run the engine with the headers attached, shut it down, remove the headers and check for water residue in the header ports to check for an occurrence of water reversion.

Your Options are:

bulletInstall extended dry pipes
bulletThis option substantially reduces if not eliminates water reversion.  With this option you can adjust where water is introduced into the exhaust stream.  Remember the longer you extend the dry pipe the louder the system becomes.
 

Home | Products | Search | Checkout | Contact Us

Rewarder Custom Headers, Inc.
590-E Constitution
Camarillo, CA  93012
Ph:  805-445-1015
Fax:  805-445-1439

Contact us at: Sales@rewarderheaders.com

Hit Counter

Copyright © 1999 Rewarder Custom Headers, Inc.